Proper AC Gas Filling with Guaranteed Leak Detection

One of the most frequent reasons an air conditioner fails to cool is the loss of refrigerant gas. Because air conditioning systems are closed loops, refrigerant does not simply "get consumed" over time. If your AC is low on gas, there is an active leak in the copper tubing, condenser bends, evaporator U-curves, or flare brass joints.

At Leo Air-conditioned and Refrigeration, we do not perform "blind top-ups" that will leak out again in a few weeks. Our technicians first locate and fix the leak using nitrogen pressure testing, braze the compromised copper section, vacuum the entire system to remove atmospheric moisture, and only then charge pure, authentic refrigerant.

Signs Your AC Needs Gas Refilling

  • Ice or Frost on Thin Copper Pipe: White frost accumulation on the outdoor discharge pipe or indoor evaporator cooling coil indicates low refrigerant pressure.
  • AC Running Continuously Without Cooling: The compressor runs non-stop without dropping room temperature, leading to excessive power consumption.
  • Hissing Noise from Indoor Unit: A faint hissing or bubbling sound from the cooling coil when refrigerant flow is starved.
  • Oily Residue on Copper Joints: Because refrigerant carries compressor lubricating oil, oily grease around flare nuts or coil bends signals a refrigerant leak point.

Our 5-Step Gas Filling Process

  1. Gauge Pressure Inspection: Testing standing and running suction pressure using specialized HVAC manifold gauges.
  2. Nitrogen Leak Testing: Pressurizing the lines with dry nitrogen gas to trace hairline pinholes and microscopic coil leaks using soap bubble solution.
  3. Copper Brazing: Oxy-acetylene / copper brazing of leaking joints, replacing damaged flare nuts or defective service valves.
  4. Deep Vacuuming: Evacuating the copper line and indoor coil using a heavy-duty vacuum pump down to 500 microns to eliminate air and moisture.
  5. Authentic Gas Charging: Charging the exact weight of factory-specified refrigerant (R32, R410A, or R22) while monitoring suction pressure and operating amperes.

Supported Refrigerants

We carry genuine, unadulterated cylinders of:

  • R-32: Modern single-component eco-friendly gas used in contemporary inverter split ACs.
  • R-410A: High-pressure dual-blend refrigerant used in modern split and VRV systems.
  • R-22: Traditional refrigerant used in classic window and split AC systems.

Frequently Asked Questions About AC Gas Filling

Why shouldn't I just top up the gas without fixing the leak?
Topping up without repairing the leak wastes money, as the newly filled gas will escape through the same hole within days or weeks. Furthermore, running on low gas causes compressor overheating and can burn out the compressor motor.
Can R32 and R410A be mixed?
No, absolutely not. Every air conditioner compressor is engineered specifically for one type of refrigerant and oil. Mixing refrigerants creates dangerous pressure spikes and destroys the compressor.
How long does the complete leak repair and gas charging process take?
A comprehensive service involving nitrogen pressurization, leak brazing, vacuum evacuation, and precision charging typically takes between 1.5 to 2.5 hours.